Library Contents Search the Library RV Tech Library Help Page Site Map About Us Tiffin RV Network TRVN Classifieds Campground Reviews Photo Gallery TRVN Store Appliances Batteries Boondocking/Dry Camping Chassis Clubs & Forums Electrical Electronics Engines Exterior Maintenance Generators Heating & Air Conditioning Interior Maintenance Misc Items Operating Tips Plumbing Red Bay Safety & Health Storage Supplier Contacts Tires and Wheel Rims Towing Transmissions Weighing |
Troubleshooting
|
WATER HEATER LOCK OUT - SPARK PRESENT BUT NO GAS |
|
CONDITION | SOLUTION |
Gas pressure incorrect | Set inlet pressure at a minimum 11" W.C. with two or more appliances running |
Low voltage | Correct power supply - 10.5 VDC minimum |
Blocked main burner tube | Clean burner tube |
Blocked main burner orifice | Clean or replace orifice |
Loose wires on E.C.O. | Secure wire connections |
Loose wire connections on solenoid valve | Secure wire connections |
Loose valve wire on wiring harness | Repair wire on edge connector or repair wiring circuit board harness |
Defective E.C.O. | Replace E.C.O. |
Defective circuit board | Replace circuit board |
Defective solenoid valve | Replace coils or solenoid valve |
No gas to solenoid valve | Correct gas supply |
Dirty connector on circuit board | Clean edge connector |
WATER HEATER LOCK OUT - GAS PRESENT BUT NO SPARK |
|
CONDITION | SOLUTION |
High tension lead wire loose | Secure wire connection on circuit board |
Electrodes loosely attached to burner | Secure electrodes to main burner |
Improper electrode gapping | Re-position spark gap to 1/8" |
Dirty electrodes | Clean electrodes |
Wires loose in electrode porcelain | Replace electrode |
Cracked porcelain on electrode | Replace electrodes |
Defective circuit board | Replace circuit board |
WATER HEATER LOCK OUT - GAS AND SPARK PRESENT |
|
CONDITION | SOLUTION |
Gas pressure incorrect | Set inlet pressure at a minimum 11: W.C. with two or more gas appliances running |
Low voltage | Correct power supply - 10.5 VDC minimum |
Poor electrical ground | Secure electrical ground |
Electrodes out of flame pattern | Re-adjust electrodes |
Electrodes sparking to screw fastening burner to flue tube | Adjust electrodes |
Dirty electrodes | Clean electrodes |
Partial obstruction in main burner | Clean main burner |
Partially obstructed main burner orifice | Clean main burner orifice |
Improper air adjustment | Adjust main burner air shutter approximately ¼ open or greater |
Flame spreader on main | Adjust flame spreader so that it is square to the end burner tube out of alignment of the main burner |
Manifold no aligned with main burner | Re-align solenoid valve with main burner |
Partially opening solenoid valve | Replace solenoid valve |
Defective circuit board | Replace circuit board |
EXCESSIVE OR INSUFFICIENT WATER TEMPERATURES |
|
CONDITION | SOLUTION |
Bypass kit valves not set properly | Place valves in proper position |
Thermostat not seated against tank | Reseat thermostat |
Defective thermostat | Replace thermostat |
Submitted by Mike Sundberg - 3/17/06
The RV Tech Library is brought to you by the TiffinRVnetwork
Absolutely No Affiliation exists between this group and Tiffin Motor Homes Inc or the Allegro Club. This website neither endorses or discourages the use or purchase of a Tiffin product. All references, suggestions, comments, etc. contained herein are the opinions/experiences of the posters and not those of Tiffin Motor Homes Inc. or the website administrators.
|